| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| This vulnerability exists in Philips lighting devices due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext Wi-Fi credentials stored on the vulnerable device.
Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the Wi-Fi network to which vulnerable device is connected. |
| The data stored in Be-Tech Mifare Classic card is stored in cleartext. An attacker having access to a Be-Tech hotel guest Mifare Classic card can create a master key card that unlocks all the locks in the building.
This issue affects all Be-Tech Mifare Classic card systems. To fix the vulnerability, it is necessary to replace the software, encoder, cards, and PCBs in the locks. |
| ToolHive is a utility designed to simplify the deployment and management of Model Context Protocol (MCP) servers. Due to the ordering of code used to start an MCP server container, versions of ToolHive prior to 0.0.33 inadvertently store secrets in the run config files which are used to restart stopped containers. This means that an attacker who has access to the home folder of the user who starts the MCP server can read secrets without needing access to the secrets store itself. This only applies to secrets which were used in containers whose run configs exist at a point in time - other secrets remaining inaccessible. ToolHive 0.0.33 fixes the issue. Some workarounds are available. Stop and delete any running MCP servers, or manually remove any runconfigs from `$HOME/Library/Application Support/toolhive/runconfigs/` (macOS) or `$HOME/.state/toolhive/runconfigs/` (Linux). |
| Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site.
This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior. |
| Insufficient encryption vulnerability in the mobile application (com.transsion.aivoiceassistant) may lead to the risk of sensitive information leakage. |
| Kaleris NAVIS N4 ULC (Ultra Light Client) communicates insecurely using zlib-compressed data over HTTP. An attacker capable of observing network traffic between Ultra Light Clients and N4 servers can extract sensitive information, including plaintext credentials. |
| Emerson ValveLink Products store sensitive information in cleartext in memory. The
sensitive memory might be saved to disk, stored in a core dump, or
remain uncleared if the product crashes, or if the programmer does not
properly clear the memory before freeing it. |
| Under certain circumstances, attacker can capture the network key, read or write encrypted packets on the PowerG network. |
| Obsidian GitHub Copilot Plugin versions prior to 1.1.7 store Github API token in cleartext form. As a result, an attacker may perform unauthorized operations on the linked Github account. |
| The web server of the Access Manager offers a functionality to download a backup of the local database stored on the device. This database contains the whole configuration. This includes encrypted MIFARE keys, card data, user PINs and much more. The PINs are even stored unencrypted. Combined with the fact that an attacker can easily get access to the backup functionality by abusing the session management issue (CVE-2025-59101), or by exploiting the weak default password (CVE-2025-59108), or by simply setting a new password without prior authentication via the SOAP API (CVE-2025-59097), it is easily possible to access the sensitive data on the device. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to use of default admin credentials at its web management interface. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the hardcoded default credentials stored in the firmware of the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure. |
| Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GT Designer3 Version1 (GOT2000) all versions and Mitsubishi Electric GT Designer3 Version1 (GOT1000) all versions allows a local unauthenticated attacker to obtain plaintext credentials from the project file for GT Designer3. This could allow the attacker to operate illegally GOT2000 series or GOT1000 series by using the obtained credentials. |
| Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to cleartext transmission of credentials in its web management interface. A remote attacker could exploit this vulnerability by intercepting the network traffic and capturing cleartext credentials.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| SAP GUI for Windows may allow a highly privileged user on the affected client PC to locally access sensitive information stored in process memory during runtime.This vulnerability has a high impact on confidentiality, with no impact on integrity and availability. |
| The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings. |
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to storage of credentials and PINS without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted data stored in the firmware of targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the network of the targeted device. |
| Arctera/Veritas Data Insight before 7.1.2 can send cleartext credentials when configured to use HTTP Basic Authentication to a Dell Isilon OneFS server. |